20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery

Brand Name : COOLNET

Model Number : CR012,CR040

Certification : CE,ISO

Place of Origin : CHINA

MOQ : 1set

Price : 1800-30000USD

Payment Terms : T/T, L/C

Supply Ability : 300 PCS PER MONTG

Delivery Time : 10-25 working days

Packaging Details : Packed in plywooden case, standard export package

Cooling capacity : 20-40KW

Mounting : Floor Standing

Type : InRow AC Units

Operating voltage : 380/400 VAC,230 VAC,220V

Warranty : 1 Year(12 month)

Product Name : InRow Precision air conditioning

Refrigerant : R410A/R407C

Application : Data Center, IT room , Computer room, Cold/hot aisle

Color : Black/Grey/White

Type of Fan : EC fan

Power : 3N-380V-50Hz,220v/50hz/60hz

Airflow : Front Flow 4500-5600m3/h

Voltage : 380v/220v,220V/380V,380V/415V

Contact Now

20-40kw In-Row Precision Air Conditioners Close To Heat Resources For Heat Recovery

Product Introduction

The Coolnet Cooling product design closely couples the cooling with the IT heat load. An unpredictable data center environment is common among IT managers. In today’s data centers, traditional cooling approaches involve complex air distribution systems that tend to be unpredictable and leave many customers guessing where the cold air goes. With the Coolnet cooling products, Placing the unit in the row of racks moves the source of cooling closer to the heat load. This minimizes air mixing and provides a predictable cooling architecture.

CoolRow is a in-row cooling solution commonly used in data centers requring higher density cooling with greater efficiency and capacity. The unit is placed beteween the servers in a row for offering cooling close to the heat load, the horizontal airflow pattern supports hot aisles and cold aisles configuration. CoolRow improves the efficiency of the overall cooling systems and ensures the steady room temperature for precise operation.

Application

  • Single rack with power larger than 3kW

  • High heat density computer room

  • Modular DC

  • Container type DC

  • DC with low PUE

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery

Air Supply Method

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery 20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery

Features

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery

Energy Efficiency

  • Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series
  • Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.
  • Cold aisle/Hot ailse containment avoids mixing of cold and hot air

High Flexibility

  • Air-cooled or chilled water-cooled cooling scheme.
  • Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

High Reliability & Serviceability

  • 24*7 uninterruptible operation design.
  • Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.
  • Secondary water tray.
  • Hot-swappable fans.
  • Highly safety performance guaranteed by functions and protections designed for the unit.

Intelligent Control System

  • Highest protection against downtime, equipment damage and excess wear and tear.
  • Touched screen interface offers the full visibility.
  • AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI and ML to provide the monitoring and reliability for a more efficient operation of the cooling system.

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery

Factory Details

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery

Packing and Delivery

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery

Case

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery


Product Tags:

Precision Air Conditioners In Row

      

Precision In Row Air Conditioning Unit

      

40 Kw Precision Air Conditioners

      
Wholesale 20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery from china suppliers

20 - 40 Kw In Row Precision Air Conditioners For Heat Recovery Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0